ISA-95
ISA-95 (IEC 62264) is the international standard for integrating enterprise and control systems. Its equipment hierarchy, from the company down to a single machine, is the most common way to structure industrial MQTT topics, and it is the structure ConnectMQ understands natively.
The equipment hierarchy
| Level | ISA-95 name | What it is | Example |
|---|---|---|---|
| L4 | Enterprise | The company | acme |
| L3 | Site | A plant or location | istanbul |
| L2 | Area | A department or production area | assembly |
| L1 | Line / work center | A production line or cell group | line1 |
| L0 | Device / work cell | One machine, robot or meter | cnc-01 |
| TAG | Signal | What the message contains | telemetry, status, cmd |
As an MQTT topic, each level becomes one topic level:
text
acme/istanbul/assembly/line1/cnc-01/telemetrySix levels stay well within ConnectMQ's limit of 8 topic levels.
Why it works well with MQTT
- Everyone finds data by where it comes from. A maintenance tool for line 1 subscribes to
acme/istanbul/assembly/line1/#; a site dashboard toacme/istanbul/#. - Wildcards follow the hierarchy.
acme/+/+/+/+/telemetryis the telemetry of every machine in the company. - Access control follows the hierarchy. One ACL rule per site or area instead of one per device.
- New sites and machines fit in without redesign. The tree grows; consumers keep working.
What ConnectMQ does with ISA-95 topics
- Topic tree and devices. The console maps the levels to Enterprise, Site, Area, Line and Device, builds the TOPICS tree and lists every device on the Devices page.
- Digital Twin. Devices are placed in the 3D scene per line and area, with their live values and alert state.
- Add Topic check. The Add Topic dialog shows ISA-95 compliant and the detected levels.
- ConnectMQ Edge. Edge publishes every PLC and meter tag in this structure out of the box.
- Automatic Sparkplug B conversion. ConnectMQ Cloud converts Sparkplug B messages into ISA-95 topics with JSON payloads, so Sparkplug devices appear in the same tree.
Other structures also work; the console then simply maps your first levels to the ISA-95 names.
Next
- Design your topics: naming rules, payloads and good practices
- Unified Namespace: using one ISA-95 tree as the plant's single source of truth
- Sparkplug B: how Sparkplug topics map to ISA-95